Welcome to join Henan Yu Bo Fire Technology Co., Ltd. official website!
河南豫博消防科技有限公司
Current position:Home page >Industry information
Industry information

" Six places , ten will look up " : Which six categories ? Look what ? Look here ! “六类场所、十项必查”:哪六类?查哪些?看这里!

Source:admin Time:2017-12-26 13:53:27 Click:

 First, "six kinds of places"

一、六类场所

( 1 ) Small gear mouth .(一)小档口。

(2) "three in one" place.(二)三合一场所。

( 3 ) Group rental housing .(三)群租房。

( 4 ) The construction site of the construction project .(四)建设工程施工现场。

(5) old-age service institutions. (五)养老服务机构

( 6 ) boarding schools . (六)寄宿制学校。   

Second, the specific contents of the "Ten items must be checked"

二、十项必查具体内容

(1) installation of leakage protection switch. All kinds of buildings (places) supply, electric lines should be installed leakage protection switch. Switch should select qualified electrical products.

(一)安装漏电保护开关。各类建筑(场所)供、用电线路均应安装漏电保护开关。开关应选用合格电气产品。

(2) Wire bushing. Protective measures shall be taken for all kinds of buildings (places) and power lines to wear metal pipes, close metal wire grooves or insulated and flame retardant PVC electrical sleeving in accordance with the national electrical technical standards.

(二)电线套管。各类建筑(场所)供、用电线路均应根据国家电气技术标准,采取穿金属管、封闭式金属线槽或者绝缘阻燃PVC电工套管保护措施。

  (3) emergency escape channel. All kinds of buildings (places) should maintain the staircase, evacuation routes, safety exit and emergency escape channel. The establishment of security fence walls are removed, residential places required to be installed, should set the length and width of the net size of not less than 1 meters, 0.8 meters and emergency escape door in the mouth, and set the ladder descent control device, and other auxiliary escape evacuation facilities.  

   (三)紧急逃生通道畅通。各类建筑(场所)均应保持楼梯间、疏散通道、安全出口等紧急逃生通道畅通。外墙设置防盗铁栅栏一律拆除,居住类场所确需安装的,应设置长宽净尺寸不小于1米、0.8米且向外开启的紧急逃生口,并设置缓降器、逃生软梯等辅助疏散设施。

  (4) physical fire separation of the joint place. Where accommodation and other productive and operational places are set up, the physical wall of the physical wall must be separated.

(四)合用场所物理防火分隔。住宿场所与其他生产经营性场所合一设置的,必须实施实体墙物理防火分隔。

  (5) the illegal occupants should be completely removed. All kinds of buildings (sites) must not be moved completely.

(五)违规住人彻底搬离。各类建筑(场所)均不得违规住人,一经发现必须彻底搬离。

  ( 6 ) Clean the electric bicycle . It is prohibited to park or charge the electric bicycle in the interior of all kinds of buildings ( places ) . Once it has been found , it must be cleaned immediately .

(六)清理电动自行车。各类建筑(场所)内部均严禁电动自行车违规停放或充电,一经发现必须立即清理。

  ( 7 ) Remove the wooden attic . All buildings ( places ) are strictly prohibited to use wooden materials to build the attic . Once they have been found , they must be forcibly removed .

(七)拆除木质阁楼。各类建筑(场所)内部均严禁采用木质材料搭建阁楼,一经发现必须强制拆除。

  (8) dismantling flammable materials. All kinds of buildings (places) are strictly forbidden to use coloured steel plates, polyurethane foam and other flammable materials, which must be dismantled as soon as they are found.

(八)拆除易燃材料。各类建筑(场所)内部均严禁使用彩钢板、聚氨酯泡沫等易燃材料,一经发现必须强制拆除。

  (9) Group rent house has clear responsibility for fire control. Strictly according to the "Ten measures to reduce Fire risk of Group Rent House", the building should be equipped with fire safety building leader, and the building length should be occupied by property service enterprise personnel or lessor. Organize and improve fire safety management system, perform daily fire safety management duties, and implement night inspection measures for full-time administrators. Accommodation of more than 3 places. Installation of independent fire alarm detector. Accommodation of more than 30 people in place, all in accordance with the standard installation of automatic fire, fire alarm and other fire fighting facilities, specifically designated to carry out 24-hour watch.

(九)群租房明确消防管理责任。严格按照《降低群租房火灾风险十项措施》要求,所在建筑应配备消防安全楼长,楼长应由物业服务企业人员或出租人担任,组织建立健全消防安全管理制度,履行日常消防安全管理职责,实施专职管理员夜间巡查措施。住宿3人以上的场所,一律加装独立式火灾报警探测器。住宿30人以上的场所,一律按照标准安装自动灭火、火灾报警等消防设施,明确专人实施24小时值守看护。

  (10) implement fire safety guarantee on construction site. Establish and improve fire safety management system in strict accordance with the requirements of "Technical Specification for Fire Control in Construction site" (GB50720-2011). In order to ensure the safety of electric power in construction, it is clear that special personnel should carry out on-site nursing, configure temporary fire fighting facilities and sufficient fire-fighting equipment, guarantee temporary fire protection water, carry out fire operations according to regulations and ensure the safety of construction electricity.

(十)施工现场落实消防安全保障。严格按照《建设工程施工现场消防技术规范》(GB50720-2011)要求,建立健全消防安全管理制度,明确专人实施现场看护,配置临时消防设施和足够灭火器材,保障临时消防用水,依法依规实施动火作业,确保施工用电安全。

Fixed telephone:0371-60940119
Address:Zheng Dong New District of Zhengzhou City Station Road West, South Lu Jiayi Eastern Mansion room 705
Copyright:Henan Yu Bo Fire Technology Co., Ltd. Prepared ICP15020209号